The superduct two wire duct smoke detector is ideally suited to applications where early indication of combustion is required within the confined space of ventilation ductwork.
Est super duct smoke detector.
Superduct duct smoke detectors will not sense smoke unless the ventilation system is operating and the sensor s cover is properly installed.
Air is introduced to the duct smoke detector s sensing chamber through a sampling tube that ext ends into the hvac duct and is directed back into the ventilation system through an exhaust tube.
Duct smoke detector 15 2 to 19 95 vdc form c auxiliary alarm relay status led product information product dimensions 6 x 11 x 4 inches.
The duct smoke detector is designed for use in duct applications where temperatures can exceed standard detector capabilities.
Superductdetectors are ideally suited to duct smoke detection applications where early indication of combustion is required within the confined space of ventilation ductwork.
Ge security sd 2w est conventional superduct duct smoke detector superduct is slim feature rich alternative to bulky duct smoke detectors.
Edwards est siga osd intelligent optical smoke detector 69 99.
The superduct duct smoke detector see figure 1 comprises a controller and one or two sensors.
Siga sd edwards est intelligent superduct detector.
Life safety consultants is here to ensure your fire and smoke detectors are always in working order.
Superduct smoke detection is ideally suited to hvac applications where early indication of combustion is required within the confined space of ventilation ductwork.
Its primary purpose is to provide early warning of an impending fire and to prevent smoke from circulating throughout the building.
Duct detectors are usually installed on the supply duct after the air filters or in the return air stream prior to being diluted by outside air.
Est edwards siga 278 intelligent double action one stage pull station red 5 0 out of 5 stars 1.
Superduct duct smoke detectors will not operate as designed outside of the listed electrical and environmental specifications.
Its primary purpose is to provide early warning of an impending fire and to prevent smoke from circulating throughout the building.
Superduct duct smoke detectors will not operate without electrical power.
Ul ulc est esd 2w two wire duct smoke detector 0 0 1 0 n a 14 ul ulc est sd 2w two wire duct smoke detector 0 0 1 0 n a 14 ul edwards 429c photoelectric smoke detector 12 24 vdc s10a n a n a 10 ul edwards 429ct photoelectric smoke detector 12 24 vdc with dual heat sensor ft ror s10a n a n a 10.
Only 18 left in stock order soon.
That s why we offer a wide range of replacement parts and components like the edwards est intelligent superduct detector siga sd.