With its super thin 4 8 mm 0 2 in titanium blade the probe can slide up to 400 mm.
Eddy current tank floor inspection.
Two types of floor scanners are used to perform the inspection of flat bottom storage tanks.
Based on the next generation mec magnetic eddy current technique innospection s capabilities in tank floor inspection with the mec floorscanners are.
Principle of mec technique the mec magnetic eddy current technique is the next generation and a further development of the slofec saturation low frequency eddy current technique.
Magnetic flux leakage mfl and surface topology air gap reluctance sensors stars featuring top and bottom plate corrosion views and capable of going as fast as 1 m s 3 2 ft s floormap improves the complete tank inspection process.
The silverwing floormap tank bottom inspection system combines two technologies.
Easy to use shielded pulsed eddy current solution reaching under tank floor edges to scan for corrosion.
This allows detection of corrosion attack metal loss even at the subsurface from the surface side.
With a combination of highly skilled personnel and a robotic tank floor inspection system techcorr provides api 653 compliant inspections of above ground storage tanks without the risk cost or hassle of removing tanks from service.
Pulsed eddy current pec inspection.
The task of the inspection system is to detect defects in tank floors walls and roofs as well as in pipe.
With this system objects with up to 25 mm wall thickness and coating up to 10 mm are testable depending on the scanner type.
Pec is an advanced electromagnetic inspection technology used to detect wall loss such as corrosion and tank thinning in ferrous materials.
Magnetic flux leakage technique predominantly for the tank floor inspection application.
The slofec inspection system is based on the eddy current principle with superimposed dc field magnetization.
The slofec inspection technique uses the eddy current principle in combination with a magnetic field.
Currently no other inspection technique can do this without emptying tanks.
High sensitivity in detecting corrosion pitting and local defects in tanks with plate thickness up to 30mm.
Pulsed eddy currents pec are perfectly suited to tackle this challenge.
Saturation low frequency eddy current inspection technique for tank floors pipes and vessels key features of the system fast screening method for local metal loss inspection of thick wall components up to 35 mm inspection through thick coating up to 10 mm inspection speeds up to 25 m min higher defect detection sensitivity than mfl.
Client a mec tank floor report page 2 of 12 tank c final inspection report k0xx 16x executive summary innospection ltd was requested by client a to perform a magnetic eddy current mec inspection on the floor plates of tank c.
Coating thickness up to 10mm.
This probe was developed for the in service inspection of storage tank floor annular rings.